The round flow cassette unit, with its high efficiency and quiet operation, is used for cooling and heating in a wide range of commercial and retail applications.
The unit supplies conditioned air from all around the unit to help create an even temperature distribution in the room with the option of also providing a fresh air supply into the unit. The output can also be set for 2-way, 3-way or 4-way air flow operation to suit the room layout. This great flexibility ensures the air conditioning system can meet the needs of the occupants even if room layouts are changed.
The low height of the unit fits well into ceiling spaces and the decoration panel, with its individually controllable flaps that close automatically when not in use, can be easily integrated into a wide range of interior decoration schemes.
Care of the unit is made easy with special coatings to maintain cleanliness and regular maintenance can be easily carried out via the detachable front panel. A drain pump is provided as standard with 850mm lift.
Models are available in the range 2.8 to 14.0kW (depending on region)
Common applications include office buildings, retail outlets, schools, restaurants etc.
VRF Air Conditioning System Parts
Yanmar VRF GHP systems are made up outdoor units, indoor unit, control devices, various accessories as well as refrigerant piping and wiring between each part of the system.
Standard VRF GHP (2 pipe)
Heat Recovery VRF GHP (3 pipe)
Indoor units
(refer to technical documentation for your region for full range of indoor units and accessories)
With a wide range of VRF indoor unit models and capacities, Yanmar GHP systems can provide high performance air conditioning solutions that meet the functional and aesthetic demands of a whole range of new and existing buildings.
Ceiling Mounted Cassette (Round Flow) Unit
Ceiling Mounted Cassette (Double Flow) Unit
With its narrow body and low height the double flow cassette unit is ideal for installation in narrow ceiling spaces such as those between light fittings.
The unit is designed to provide comfortable heating and cooling with quiet operation, the option also exists to provide a fresh air supply into the unit. Airflow is distributed evenly by auto swing flaps that can be controlled separately and can also be set to keep the ceiling around the unit clean. The flaps close automatically when the unit is not in operation to preserve the line of the ceiling.
Regular maintenance can easily be carried out by removing the front panel. A drain pump is provided as standard with 600mm lift.
Models are available in the range 2.2 to 14.0kW (depending on region)
Common applications include offices buildings, meeting rooms, schools etc.
Ceiling Mounted Cassette (Single Flow) Unit
With its single air outlet and auto swing flap the single flow cassette is ideal for producing a flow of conditioned air from the edge of a room. The unit operates very quietly and its very low height means it can be installed in very narrow ceiling spaces. It can also configured with a sideways air outlet to make an effective solution for drop ceiling installations even with a shallow ceiling step height.
The unit auto swing flap helps to create an even airflow and temperature distribution in the room, the flap can also be set to keep the ceiling around the unit clean and automatically closes when the unit is not in use.
A drain pump with 500mm lift is provided as standard and regular maintenance can easily be carried out by removing the front panel.
Models are available in the range 2.8 to 7.1kW (depending on region)
Common applications include hotels, retail outlets, schools, offices , restaurants etc.
Ceiling Suspended Unit
The ceiling suspended unit is ideal for installation in rooms in new or existing buildings where there is little or no ceiling space. Being low in height, and requiring minimal clearance around the unit, it can be installed unobtrusively on the ceiling close to room walls or corners.
The unit delivers comfortable heating and cooling with its high airflow output and wide air outlet guides that help distribute air from the unit over a wide area. The fan used in the unit is specially designed to provide a powerful output with smooth air flow allowing the unit to operate very quietly.
The unit is easy to clean and all regular maintenance can be done easily from under the unit. A drain pump with a lift of 600mm is available as an option.
Models are available in the range 3.6 to 11.2kW (depending on region)
Common applications include retail outlets, restaurants, classrooms, conference rooms etc.
Ceiling Mounted Duct (Slim Type) Unit
The slim type ceiling mounted duct unit with its low height and compact design can easily be installed behind ceilings where vertical space is limited. Since only the suction and discharge grilles are visible installation of the unit has minimal impact on interior design of the room space. This combined with the extremely low operating sound (29dBA for smaller units), made possible by the special design of fan used in the unit, makes it ideal for sensitive applications like hotel guest rooms. In addition, 3 levels of air flow volume and 2 levels of external static pressure can be set via the remote control unit with the unit producing enough static pressure for connection to smaller scale duct systems. This flexibility makes it possible to use the unit in a wide range of cooling and heating system designs.
A drain pump is provided as standard with 750mm lift.
Models are available in the range 2.2 to 7.1kW (depending on region)
Common applications include office buildings, hotels, hospitals, care homes etc.
Ceiling Mounted Duct (High External Static Pressure) Unit
This model of ceiling mounted duct unit produces higher external static pressure making it possible to connect the unit to more extensive duct systems for the cooling and heating of larger areas. Impact on interior design can minimized with this unit by building the unit and ducting into ceilings etc. so that only air inlet and outlet ducts are visible.
System design and commissioning are made easier with this unit with its easily adjustable external static pressure and also airflow control via remote controller. The unit has an optional built in drain pump to minimize installation space and special coatings to maintain the long term performance of the system.
Models are available with capacities of 22.4 and 28.0kW (depending on region).
Common applications include office buildings, restaurants, retail outlets, event rooms etc.
Wall Mounted Unit
The wall mounted unit with its compact body and clean lines is designed to blend into a wide range of interior decoration schemes. The unit line up also includes smaller capacity models making the wall mounted unit suitable for the cooling and heating of even small rooms. The unit operation is very quiet and the vertical auto-swing flap ensures the room is cooled or heated evenly. In addition, the auto-swing flap can be set to one of five positions and closes automatically when the unit is not in use.
Being wall mounted there is little disturbance to the room interior which also makes this unit very suitable for installation in existing buildings.
The exterior of the unit is easy to clean and the filter can be removed for washing.
A drain can be fitted to either side of the unit and a drain pump is provided as an optional accessory.
Models are available in the range 2.2 to 7.1kW (depending on region)
Common applications include offices, meeting rooms, restaurants, hotel bedrooms etc.
Floor Standing Unit
The floor standing unit is designed to provide a convenient solution for the cooling and heating of perimeter areas and its low height makes it perfect for installation under windows. The unit can also be installed as a wall mounted unit with its feet removed to make clear space under the unit.
For existing buildings, especially where previous equipment was fitted around the room perimeter, this unit provides a convenient replacement and with smaller capacity models also included in the line up it becomes a good solution even for smaller rooms.
Maintenance is easy to carry out from the room side of the unit and a long life washable filter is fitted as standard.
Models are available in the range 2.2 to 7.1kW (depending on region)
Common applications include offices, multi-family residences, places of worship, historic buildings, schools etc.
Branch selector units
(refer to technical documentation for your region for full range of branch selector units and accessories)
Branch selector units connect between EFZP series outdoor units and indoor units. They allow the system to provide simultaneous cooling and heating by controlling the flow of refrigerant between indoor units without passing through the outdoor unit. In this way the branch selector units make it possible to reclaim heat energy from one part of the building and use it in another which increases the efficiency of the whole system.
Models are available that allow connection of several indoor units with combined cooling capacities in three ranges ( up to 11.2kW, between 11.2 kW and 18.0kW, between 18.0kW to 28.0kW)
Applications include buildings where there are temperature differences between different zones due to solar gain or other factors.
Control devices
(refer to technical documentation for your region for full range of control devices and accessories)
VRF GHP air conditioning systems provide flexible heating and cooling solutions for a wide range of applications and an important part of that flexibility comes from system control. Yanmar offers a wide range of controller options to bring comfort and convenience to system users and facility managers.
Options are available to control the system locally, centrally or by interfacing with building control systems.
Local controllers provide control over individual or small groups of indoor units.
Some parameters can be locked to allow a basic degree of system management.
Central controllers provide control over larger numbers of indoor units.
Functions include group operation scheduling as well as functions for managing systems in multi-tenant buildings.
Building control system interfaces provide great flexibility and easy expansion of the number of indoor units.
Controller Examples
Local Controllers
The Navigation Remote Controller is a wired remote controller offering control of up to 16 indoor units. As well as control over basic operation parameters such as temperatures, fan speeds, louvre swing etc. the controller also offers scheduling and password setting functions for basic system management.
Central Controllers (used alone or in combination with each other)
The Central Controller can control up to 128 indoor units with up to 64 groups (128 groups possible using two controllers). Group control and zone (multi-group) control is available with extended timer functions.
The Schedule Timer can control up to 128 indoor units with up to 64 groups. The unit provides convenient control with up to 8 types of weekly schedule.
Refer to tech manuals for details. Specifications may change without notice.
Building Control System Interfaces
A range of building control system interfaces is available that allow control of GHP systems via a range popular control protocols.
Outdoor unit accessory examples
(refer to technical documentation for your region for full range of outdoor unit accessories)
Anti vibration base
Yanmar GHP units are designed to operate with very low noise and vibration, but for applications where it is necessary an anti-vibration mount is available as an option for each outdoor unit model (depending on region).
The anti-vibration mount decouples the GHP unit and the building structure so sound energy within the GHP body is not transmitted to the building. It is very common to use this kind of anti-vibration mount when installing equipment such as air conditioning units, pumps etc. on building structures.
Air Direction Adjuster
The air direction adjuster is an optional stainless steel hood that attaches to the top of a Yanmar GHP outdoor unit. Its primary function is to change the direction of the air being discharged from the top of the GHP unit but it is also used to protect the unit from snow build up in colder climates.
Where the upward flow of discharged air away from the top of the GHP unit is impeded by a surrounding structure, the direction adjuster can be used to improve the flow of away from the unit. This helps to maintain a fresh flow of ambient temperature air to the rest of the unit and reduces any thermal effect of the discharged air on the surrounding structure.
In colder climates snow and ice can build up on the top the GHP unit and impede the performance of the unit. This can be avoided by fitting the air direction adjuster hood to shield the top of the unit.